BACHARACH MGD-100 Gas Detector

Previous 5 / 17 Next

BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector BACHARACH MGD-100 Gas Detector Fixed Gas Leak Detector
Quantity
Add Quotation


Scalable Gas Detection System
  • Infrared or semiconductor sensor options
  • System solution for 1, 2, 4 or 6 sensors
  • Detects refrigerants, CFC, HCFC, HFC, Ammonia, Carbon Dioxide and combustible gases
  • IP66 housing options, including remote and duct mount sensors
  • Built-in relay for 1 or 2 pre-set alarm levels

Description

The MGD-100 is an affordable and scalable gas detection system used to provide real-time monitoring of refrigerant and combustible gases, ammonia and carbon dioxide. The unit alarms when pre-set thresholds are exceeded. Alarms are monitored by a centralized controller, which can alert personnel of potential hazardous conditions via an onboard buzzer and LED alarm indicators.

The unit can be configured from single-sensor, one-alarm level system to larger scale systems consisting of 6 sensors with 2 alarm levels. The instruments are connected to and powered by the MGD controller. A variety of housing options are available including IP41 and IP66 rated enclosures, which enable direct placement of the MGD-100 in a variety of environments. For special applications, the sensor can be remotely mounted from the instrument.
 

Specifications

Type

Gas detector using IR or semiconductor sensor

Gases

Refrigerants:

Ammonia (NH3), Carbon Dioxide (CO2), Hydrocarbons, and HFCs, HCFCs, CFCs

Combustible gases:

Methane (CH4), Propane (C3H8), Butane (C4H10), LPG, and Hydrogen (H2)

Measuring Range *

ppm, %LEL or Vol%

Status Indicators

1 alarm system green and red LEDs

2 alarm system green, yellow and red LEDs

Power Supply

12 VDC or 100-230 VAC 60 / 50 Hz

Distance of Sensor from Controller

1 or 2 sensor 200 ft (60 m); 4-wire

4 or 6 sensor 500 ft (150 m); 4-wire

Audible Alarm

Buzzer

Relay *

1 or 2 alarm relay, SPDT

Rating 10 A @ 120 / 230 VAC, resistive load

Ambient Conditions*

Temperature


 

IP41 - 4 to +122 °F (- 20 to +50 °C)

IP66 - 40 to +122 °F (- 40 to +50 °C)

Humidity

0 to 95 %RH, non condensing

Altitude

0 to 10,000 ft (3,050 m)

Controller Enclosure

powder coated aluminum, M20 cable gland, IP51

Size (w x h x d)

Approx.

1 or 2 sensors 4.1” x 8.4” x 3.2” / 105 x 215 x 85 mm

4 or 6 sensors 10.4” x 10.3” x 3.3” / 265 x 265 x 85 mm

Weight Approx.

1 or 2 sensors 2.9 lbs / 1.3 kg

4 or 6 sensors 5.7 lbs / 2.6 kg

Instrument Enclosure

ABS; M20 cable gland

Size (w x h x d)

Approx. *

IP41 3.4” x 5.6” x 2.1” (90 x 145 x 55 mm)

IP66 6.5” x 6.9” x 3.3” (165 x 175 x 85 mm)

Ex d 5.2” x 6.3” x 3.6” (135 x 160 x 95 mm)

Weight Approx.*

IP41 6.3 oz (180 g)

IP66 22 oz (623 g)

Ex d 9.3 lbs (4.2 kg)

Approvals

CE, UL, CSA, IEC, EN 61010-1

* See datasheet for details

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Contact Us


Only allowed jpg, jpeg, doc, docx and pdf with 2MB maximum filesize.
Switch to Mobile Version